Title :
Inverting faults in a three phase line commutated DC drive
Author_Institution :
Reliance Electr. Co., Athens, GA, USA
Abstract :
The various factors that result in an insufficient thyristor turn-off time and a resulting inverter failure are discussed. A recommended maximum converter voltage for typical industrial conditions is also presented. Data from a laboratory test setup are tabulated to confirm the results.<>
Keywords :
DC motors; commutation; electric drives; electrical faults; invertors; thyristor applications; inverter failure; power convertors; three phase line commutated DC drive; thyristor turn-off time; voltage; AC motors; Armature; Circuit faults; Commutation; Inductance; Induction motors; Machine windings; Servomotors; Thyristors; Voltage;
Conference_Titel :
Industry Applications Society Annual Meeting, 1989., Conference Record of the 1989 IEEE
Conference_Location :
San Diego, CA, USA
DOI :
10.1109/IAS.1989.96757