Automatic Thresholding of Micro-CT Trabecular Bone Images
Author :
Zhang, Yongping ; He, Zhongkun ; Fan, Shaojing ; He, Kejia ; Li, Chen
Author_Institution :
Sch. of Electron. & Inf. Eng., Ningbo Univ. of Technol., Ningbo
Volume :
2
fYear :
2008
fDate :
27-30 May 2008
Firstpage :
23
Lastpage :
27
Abstract :
This paper considers the problem associated with the segmentation of trabecular bone image obtained from micro-computed tomography (microCT). The morphometric indices of a 3D bone image, which are associated with the trabecular bone strength, may play an important clinical role in early predictions of osteoporosis onset and in longitudinal studies of different medical treatments for osteoporosis. Correct estimation of morphologic parameters requires accurate segmentation of bone images. In the present approach, a connectivity-preserving threshold algorithm, connectivity stable thresholding (CST), is introduced. The algorithm is based on the coupling of topological parameter Conn.D and geometric parameter structure model index (SMI) to select an optimal threshold. The experimental results indicate that CST gives good results.
Keywords :
bone; computerised tomography; diagnostic radiography; image segmentation; medical image processing; 3D bone image; automatic thresholding; connectivity stable thresholding; image segmentation; microCT trabecular bone images; microcomputed tomography; morphometric indices; osteoporosis; Biomedical engineering; Cancellous bone; Helium; Image segmentation; Microstructure; Osteoporosis; Shape; Solid modeling; TV; Tomography; Trabecular bone; microCT imaging; morphometric indices; thresholding;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
BioMedical Engineering and Informatics, 2008. BMEI 2008. International Conference on
Conference_Location :
Sanya
Print_ISBN :
978-0-7695-3118-2
Type :
conf
DOI :
10.1109/BMEI.2008.13
Filename :