• DocumentCode
    1939273
  • Title

    Definition of quality criterion for the sealing seam obtained by ultrasonic welding of containers with blood specimens

  • Author

    Khmelev, Vladimir N. ; Tsyganok, Sergey N. ; Barsukov, Roman V. ; Levin, Sergey V.

  • Author_Institution
    Biysk Technol. Inst., Russia
  • fYear
    2004
  • fDate
    1-5 July 2004
  • Firstpage
    149
  • Lastpage
    151
  • Abstract
    In this paper the basic problems limiting the development of the systems of automatic definition quality of ultrasonic welding are shown. Results of researches by definition criterion of quality ultrasonic welding on stationary and manual device are presented. The authors have presented an ultrasonic welder with a manual working tool, allowing in an automatic mode to determine the quality of the formed weld seam.
  • Keywords
    piezoceramics; seals (stoppers); ultrasonic welding; automatic definition quality; automatic mode; blood specimens; manual working tool; sealing seam; ultrasonic welder; ultrasonic welding; weld seam; Acoustic bonding; Ceramics; Piezoelectric materials; Seals;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electron Devices and Materials, 2004. Proceedings. 5th Annual. 2004 International Siberian Workshop on
  • Print_ISBN
    5-7782-0463-9
  • Type

    conf

  • DOI
    10.1109/PESC.2004.241276
  • Filename
    1358328