Title :
On Image Registration in Magnetic Resonance Imaging
Author :
Qiu, Peihua ; Nguyen, Tram
Author_Institution :
Sch. of Stat., Minnesota Univ., Minneapolis, MN
Abstract :
Image registration is used in many fields for mapping one image to another. In magnetic resonance imaging (MRI) applications, one of the main uses is for correction of motion- induced artifacts so that subsequent image analysis would be more reliable. This paper gives an introduction to some image registration problems in MRI and functional MRI applications, describes certain commonly used image registration procedures, and discusses their major features. Two potential research topics for improving current image registration procedures are also discussed.
Keywords :
biomedical MRI; image registration; medical image processing; functional MRI applications; image registration; magnetic resonance imaging; motion-induced artifacts; Biomedical monitoring; Coils; Image registration; Magnetic fields; Magnetic resonance; Magnetic resonance imaging; Medical treatment; Pathology; Radio frequency; Working environment noise; MRI; fMRI; image registration; image restoration; transformations;
Conference_Titel :
BioMedical Engineering and Informatics, 2008. BMEI 2008. International Conference on
Conference_Location :
Sanya
Print_ISBN :
978-0-7695-3118-2
DOI :
10.1109/BMEI.2008.33