DocumentCode
1941410
Title
Interior permanent magnet machine analysis using finite element based equivalent circuit model
Author
Stanton, S. ; Lin, D. ; Tang, Z.
Author_Institution
Ansoft LLC, A Subsidiary of ANSYS, Pittsburgh, PA, USA
fYear
2009
fDate
7-10 Sept. 2009
Firstpage
291
Lastpage
294
Abstract
Due to the high local magnetic saturation, interior permanent magnet (IPM) brushless and synchronous machines are normally simulated based on finite element analysis (FEA). This paper presents a simulation approach based on the equivalent circuit extraction (ECE) model from FEA results. A high efficient sweep technique is introduced and the simulation results for an IPM machine are compared with the transient FEA results and the test data.
Keywords
brushless machines; equivalent circuits; finite element analysis; permanent magnet machines; synchronous machines; equivalent circuit model; finite element analysis; interior permanent magnet brushless machine; interior permanent magnet machine analysis; local magnetic saturation; synchronous machine; Analytical models; Circuit simulation; Data mining; Equivalent circuits; Finite element methods; Magnetic analysis; Permanent magnet machines; Permanent magnets; Saturation magnetization; Synchronous machines; Equivalent circuit extraction; finite element analysis; interior permanent magnet; synchronous machine; system simulation;
fLanguage
English
Publisher
ieee
Conference_Titel
Vehicle Power and Propulsion Conference, 2009. VPPC '09. IEEE
Conference_Location
Dearborn, MI
Print_ISBN
978-1-4244-2600-3
Electronic_ISBN
978-1-4244-2601-0
Type
conf
DOI
10.1109/VPPC.2009.5289839
Filename
5289839
Link To Document