DocumentCode :
1946613
Title :
RF safety of wires in interventional MRI: using a safety index
Author :
Yeung, Christopher J. ; Susil, Robert C. ; Atalar, Ergin
Author_Institution :
Dept. of Biomed. Eng., Johns Hopkins Univ., Baltimore, MD, USA
Volume :
3
fYear :
2001
fDate :
2001
Firstpage :
2496
Abstract :
With the rapid growth of interventional MRI, radiofrequency (RF) heating at the tips of guidewires, catheters, and other wire-shaped devices has become an important safety issue. Previous studies have identified some of the variables that affect the relative magnitude of this heating but none could predict the absolute amount of heating to formulate safety margins. This study presents the first theoretical model of wire tip heating that can accurately predict its absolute value. The method of moments was used to find the induced currents on insulated and bare wires that were completely embedded in the tissue. The induced currents caused an amplification of the local specific absorption rate (SAR) distribution near the wire. This SAR gain was combined with a semi-analytic solution to the bioheat transfer equation to generate a safety index. The safety index is a measure of the worst case in vivo temperature change that can occur with the wire in place. It can be used to set limits on the spatial peak SAR of pulse sequences that are used with the interventional wire. Under worst-case conditions with resonant wires in a poorly perfused tissue, only about 100 mW/kg/°C spatial peak SAR may be used at 1.5 T. But for ≤10 cm wires with insulation thickness ≥30% of the wire radius that are placed in well perfused tissues, normal operating conditions of 4 W/kg spatial peak SAR are possible at 1.5 T. We propose a simple way to ensure safety when using an interventional wire: set a limit on the SAR of allowable pulse sequences that is a factor of a safety index below the tolerable temperature increase.
Keywords :
biological tissues; biomedical MRI; biothermics; catheters; health hazards; method of moments; radiofrequency heating; surgery; 1.5 T; 10 cm; RF safety; SAR gain; absolute value; bare wires; bioheat transfer equation; catheters; guidewires; heating; in vivo temperature change; induced currents; insulated wires; insulation thickness; interventional MRI; local specific absorption rate distribution; method of moments; normal operating conditions; poorly perfused tissue; pulse sequences; radiofrequency heating; resonant wires; safety index; semi-analytic solution; spatial peak SAR; theoretical model; tissue; tolerable temperature increase; well perfused tissues; wire radius; wire tip heating; wire-shaped devices; wires; worst-case conditions; Cable insulation; Catheters; Heating; Magnetic resonance imaging; Predictive models; Radio frequency; Radiofrequency identification; Safety devices; Temperature; Wires;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, 2001. Proceedings of the 23rd Annual International Conference of the IEEE
ISSN :
1094-687X
Print_ISBN :
0-7803-7211-5
Type :
conf
DOI :
10.1109/IEMBS.2001.1017285
Filename :
1017285
Link To Document :
بازگشت