DocumentCode
1948624
Title
Detection of masses in mammography through redundant expansions of scale
Author
Laffont, V. ; Durupt, F. ; Birgen, M.A. ; Bauduin, S. ; Laine, A.F.
Author_Institution
Ecole Centrale de Nantes, France
Volume
3
fYear
2001
fDate
2001
Firstpage
2797
Abstract
We show that dyadic scales may not be sufficient for the detection of masses in mammograms: a lesion may be too blurred on one scale, and then too fragmented at the next. In this paper, we report on the preliminary evidence of our study using a continuous wavelet transform in two dimensions with arbitrary positioning of a wavelet´s center frequency channel tuned to the mass detection problem. Our goal is to detect masses in dense mammograms whose diameter is smaller than 1 cm. The aim is to be able to find the scale where the mass is best represented in terms of analysis.
Keywords
cancer; mammography; medical image processing; wavelet transforms; 1 cm; arbitrary positioning; blurred lesion; breast cancer; dyadic scales; fragmented lesion; mammographic masses; mass detection problem; medical diagnostic imaging; redundant scale expansions; wavelet´s center frequency channel; Biomedical engineering; Continuous wavelet transforms; Discrete wavelet transforms; Equations; Frequency; Lattices; Lesions; Mammography; Speech analysis; Wavelet transforms;
fLanguage
English
Publisher
ieee
Conference_Titel
Engineering in Medicine and Biology Society, 2001. Proceedings of the 23rd Annual International Conference of the IEEE
ISSN
1094-687X
Print_ISBN
0-7803-7211-5
Type
conf
DOI
10.1109/IEMBS.2001.1017366
Filename
1017366
Link To Document