    A real-time intrauterine catheter technique for fetal electrocardiogram monitoring

  • Author

    Horner, S.L. ; Holls, W.M.

  • Author_Institution
    Dept. of Electr. Eng., Bucknell Univ., Lewisburg, PA, USA
  • Volume
    3
  • fYear
    2001
  • fDate
    2001
  • Firstpage
    3066
  • Abstract
    A fetal electrocardiogram (FECG) obtained via an intrauterine catheter (IC) is a compromise between the clinically accepted invasive scalp electrode, and the noninvasive abdominal wall approaches. The catheter is inserted into the uterus during delivery, but is non-invasive to the fetus. The IC can be modified to contain a pressure sensor to monitor contractions. The modified IC would enable fetal heart rate and contractions to be monitored with one sensor. Currently, two sensors that include the invasive scalp electrode and intrauterine pressure catheter are used clinically. Signal processing is required to obtain a FECG via the IC. Usually the maternal electrocardiogram (ECG) is present in the IC´s signal along with electromyographic noise. Obtaining the FECG in real-time further complicates the processing since the FECG can be similar in amplitude to the maternal ECG. Current techniques for maternal ECG cancellation produce a significant residual during the initial processing of the algorithm and/or falsely detect the FECG for the maternal ECG. A real-time IC technique is discussed. The results from clinical data from eight patients indicate a FECG with a good signal-to-noise ratio can be obtained even during the first seconds and minutes of operation.
  • Keywords
    biomechanics; catheters; electrocardiography; medical signal detection; medical signal processing; obstetrics; patient monitoring; pressure sensors; real-time systems; amplitude; clinical data; clinically accepted invasive scalp electrode; contraction monitoring; electromyographic noise; false detection; fetal electrocardiogram monitoring; fetal heart rate; intrauterine pressure catheter; invasive scalp electrode; maternal ECG cancellation; noninvasive abdominal wall approach; pressure sensor; real-time intrauterine catheter technique; signal processing; signal-to-noise ratio; uterus; Abdomen; Catheters; Electrocardiography; Electrodes; Fetal heart rate; Fetus; Integrated circuit noise; Monitoring; Scalp; Signal processing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, 2001. Proceedings of the 23rd Annual International Conference of the IEEE
  • ISSN
    1094-687X
  • Print_ISBN
    0-7803-7211-5
  • Type

    conf

  • DOI
    10.1109/IEMBS.2001.1017448
  • Filename
    1017448