DocumentCode :
1952743
Title :
Investigation of Double-Chamber Series Valveless Micropump: An Analytical Approach
Author :
Azarbadegan, A. ; Moeendarbary, E. ; Cortes-Quiroz, C.A. ; Eames, I.
Author_Institution :
Dept. of Mech. Eng., Univ. Coll. London, London, UK
fYear :
2010
fDate :
10-16 Feb. 2010
Firstpage :
107
Lastpage :
112
Abstract :
We describe an analytical study of the characteristics of a double-chamber series valveless micropump using a one-dimensional non-linear model. We derive a closed-form expression for relationship between the mean volume flux, pressure difference and measurable characteristics of the pump. To first order, the results show the linear decrease of the volume flux with the pressure difference, which is consistent with other types of valveless pump configurations.
Keywords :
micropumps; valves; closed-form expression; double-chamber series valveless micropump; mean volume flux; one-dimensional non-linear model; pressure difference; valveless pump configurations; Analytical models; Closed-form solution; Educational institutions; Frequency; Lab-on-a-chip; Mathematical model; Mechanical engineering; Micropumps; Nanoelectromechanical systems; Valves; Analytical Modeling; Lab-on-a-Chip; Micro-Pump; Valveless Series-Pump;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Quantum, Nano and Micro Technologies, 2010. ICQNM '10. Fourth International Conference on
Conference_Location :
St. Maarten
Print_ISBN :
978-1-4244-5807-3
Type :
conf
DOI :
10.1109/ICQNM.2010.27
Filename :
5437772
Link To Document :
بازگشت