• DocumentCode
    1954768
  • Title

    Real-time imaging based quantification of microbubbles concentration and velocity vector quality evaluation using texture analysis method for ultrasonic particle image velocimetry technique

  • Author

    Niu, Lili ; Qian, Ming ; Jin, Qiaofeng ; Jiang, Bo ; Zheng, Hairong

  • Author_Institution
    Paul C. Lauterbur Res. Center for Biomed. Imaging SIAT, Chinese Acad. of Sci., Shenzhen, China
  • fYear
    2010
  • fDate
    11-14 Oct. 2010
  • Firstpage
    1315
  • Lastpage
    1318
  • Abstract
    Previous studies showed that the concentration of ultrasound contrast agents (UCAs) during imaging would impact greatly on the accuracy of flow velocity measurements using ultrasonic particle image velocimetry (Echo PIV) technique. This paper presents a texture-based method to identify the optimum concentration of UCAs for Echo PIV. The first-order and seconded-order texture features, standard deviation, contrast, energy and homogeneity, are extracted from ultrasound images of in vitro rotational flow (10MHz) and in vivo rat (30MHz) common carotid arterial flow with UCAs at various concentrations. The results show that the optimum UCAs concentration is 0.8~2×103 bubbles/ml in vitro and 1~5×105 bubbles/ml in vivo, therein high accurate velocity vectors are obtained by Echo PIV. Otherwise, poor quality velocity vectors are yielded. The accuracy of K-nearest neighbor classifier reaches 86.4% in vitro. Thus, texture features could be used to identify the optimum UCAs concentration in real time for Echo PIV.
  • Keywords
    biomedical ultrasonics; blood vessels; feature extraction; image texture; medical image processing; physiological models; first-order texture features; frequency 10 MHz; frequency 30 MHz; in-vitro rotational flow; in-vivo rat common carotid arterial flow; microbubble concentration; real-time imaging based quantification; second-order texture feature; standard deviation; texture analysis method; ultrasonic particle image velocimetry technique; ultrasound contrast agents; velocity vector quality evaluation; Acoustics; Fitting; Imaging; In vitro; In vivo; Real time systems; Ultrasonic imaging; Echo PIV; Microbubble; Texture analysis; UCAs;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium (IUS), 2010 IEEE
  • Conference_Location
    San Diego, CA
  • ISSN
    1948-5719
  • Print_ISBN
    978-1-4577-0382-9
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2010.5935600
  • Filename
    5935600