Abstract
Prony´s method is effective for decomposing two component pulses into two-separate constituent pulses. This has applications for ultrasonic characterization of bone.
Keywords
biomedical ultrasonics; bone; phantoms; Prony´s method; bone; phantom; two-component pulse decomposition; ultrasonic characterization; Acoustics; Attenuation; Biological system modeling; Bones; Cancellous bone; Materials; Phantoms; cancellous bone; phase velocity;