DocumentCode :
1955926
Title :
Three-dimensional digital sonomicrometry: comparison with biplane radiography
Author :
Meoli, D. ; Mazhari, R. ; Dione, Donald ; Omens, Jeffrey ; McCulloch, Andrew ; Sinusas, Albert
Author_Institution :
Dept. of Med., Yale Univ., New Haven, CT, USA
fYear :
1998
fDate :
9-10 Apr 1998
Firstpage :
64
Lastpage :
67
Abstract :
Describes a three-dimensional (3D) digital sonomicrometry approach for locating and tracking 3D objects. A commercial digital sonomicrometry system was employed to measure scalar distances between omnidirectional sonomicrometers. 3D coordinates were then derived using the statistical technique of multidimensional scaling (MDS). 3D digital sonomicrometry was directly compared with biplane radiography of the ultrasound crystals for estimation of 3D distances in static phantoms and in vivo using an experimental canine preparation. An excellent correlation (r=0.992) was seen when comparing intercrystal distances derived from biplane radiography and sonomicrometry 3D coordinate data in the gelphantom. A Bland-Altman analysis shows that the average difference in coordinate determined distance between these two different methodologies was only 0.6310.46 mm, over a range of inter-crystal distances of 3.14 to 17.28 mm. In the in vivo canine preparation, the correlation between the sonomicrometry derived and biplane derived distances was also excellent (r=0.992) with a slope of 1.05 and an intercept of 0.06. The Bland-Altman analysis shows that the average difference in coordinate determined distance between these two different methodologies was only 0.78±0.74 mm, over a range of inter-crystal distances of 2.90 to 27.66 mm. The authors have demonstrated the feasibility of accurately measuring scalar distances using 3D digital sonomicrometry. Digital sonomicrometry combines high spatial and temporal resolution with availability and portability to accurately measure distances in a closely packed array of implanted piezoelectric crystals
Keywords :
biomedical measurement; biomedical ultrasonics; diagnostic radiography; distance measurement; 3.14 to 27.66 mm; 3D objects location; 3D objects tracking; Bland-Altman analysis; biplane radiography; experimental canine preparation; implanted piezoelectric crystals; multidimensional scaling; omnidirectional sonomicrometers; scalar distances measurement; static phantoms; statistical technique; three-dimensional digital sonomicrometry; ultrasound crystals; Availability; Coordinate measuring machines; Crystals; Imaging phantoms; In vivo; Multidimensional systems; Radiography; Spatial resolution; Ultrasonic imaging; Ultrasonic variables measurement;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Bioengineering Conference, 1998. Proceedings of the IEEE 24th Annual Northeast
Conference_Location :
Hershey, PA
Print_ISBN :
0-7803-4544-4
Type :
conf
DOI :
10.1109/NEBC.1998.664878
Filename :
664878
Link To Document :
بازگشت