DocumentCode
1957474
Title
Improved plane-wave high frame rate imaging using retrospective transmit focusing and filter-derived coherence-index weighting
Author
Hu, Chang-Lin ; Jeng, Geng-Shi ; Wang, Yu-Hsin ; Li, Pai-Chi ; Li, Meng-Lin
Author_Institution
Dept. of Electr. Eng., Nat. Tsing Hua Univ., Hsinchu, Taiwan
fYear
2010
fDate
11-14 Oct. 2010
Firstpage
1916
Lastpage
1919
Abstract
Recently, a wide spectrum of new applications in biomedical ultrasound such as real time 3D ultrasound and transient elastography has triggered the need of high frame-rate imaging. One of the methods to achieve high frame-rate imaging is to use plane wave excitation (PWE) with which a single insonification is sufficient to form an image. However, due to the lack of transmit focusing, the signal-to-noise-ratio (SNR), contrast, and spatial resolution of the resultant images are lower compared with a conventional focused transmission. To solve this problem, we propose a filter-based retrospective focusing technique combined with filter-derived coherence-index weighting (FRF+FCI weighting) for high frame-rate imaging with PWE. A 2-D filter is designed and applied to beamformed baseband data to retrieve transmit focusing. Then a filter-derived coherence index (FCI) at each imaging point is used as a weighting factor to further improve the filter-retrieved focusing quality. Here FCI is a coherence measure of the filtered signal samples in the sliding filter kernel, Due to the sidelobe-suppression nature of the designed 2-D filter, FCIs are low at sidelobes; thus FCI weighting can further suppress the sidelobes in the filtered signal samples. Simulation results demonstrated that our proposed FRF+FCI weighting technique can enhance the image quality of high frame-rate imaging with single PWE reducing the sidelobes, and improving the SNR and spatial resolution while being capable of retaining the high frame rate. Since it is applied over high frame-rate imaging with single PWE, FRF+FCI weighting performed after beamforming is inherently insusceptible to motion artifacts. In addition, coded excitation techniques can be integrated into our technique to further improve SNR.
Keywords
array signal processing; biomedical ultrasonics; filtering theory; image resolution; medical image processing; ultrasonic focusing; FRF+FCI weighting; PWE; SNR; beamforming; biomedical ultrasound; coded excitation; filter-based retrospective focusing; filter-derived coherence-index weighting; high frame rate imaging; image contrast; image resolution; plane wave excitation; real time 3D ultrasound; retrospective transmit focusing; signal-to-noise-ratio; transient elastography; Acoustics; Baseband; Coherence; Focusing; Signal to noise ratio; Ultrasonic imaging; High frame rate imaging; coherence weighting; plane wave excitation; retrospective focusing;
fLanguage
English
Publisher
ieee
Conference_Titel
Ultrasonics Symposium (IUS), 2010 IEEE
Conference_Location
San Diego, CA
ISSN
1948-5719
Print_ISBN
978-1-4577-0382-9
Type
conf
DOI
10.1109/ULTSYM.2010.5935716
Filename
5935716
Link To Document