DocumentCode
1957511
Title
Muscle force estimation using data fusion from high-density SEMG grid
Author
Allouch, S. ; Al Harrach, M. ; Boudaoud, S. ; Laforet, J. ; Ayachi, F.S. ; Younes, R.
Author_Institution
Biomech. & Bio-Eng., Univ. of Technol. of Compiegne (UTC), Compiegne, France
fYear
2013
fDate
11-13 Sept. 2013
Firstpage
195
Lastpage
198
Abstract
The aim of the proposed work is to evaluate, by simulation, the introduction of a data fusion process from a HD-sEMG grid (8×8) to improve the muscle force estimation from sEMG signal. For this purpose, twelve electrode arrangements are combined to dimension reduction technique (PCA or channel averaging) to obtain a monodimensional sEMG signal. After, this signal is used in a sEMG-force relationship model to estimate the muscular force. In fact, two models, with different complexity, and used in the biomechanics community are studied. In the simulation, three isometric contractions are simulated (20%, 50% and 80% MVC) using a recent sEMG-force generation model. Finally, the Normalized RMS Difference (NRMSD) between the estimated force and the simulated force by the sEMG-force generation model is calculated for each combination (electrode arrangement and dimension reduction technique, force estimator). According to the obtained results, the combination PCA and Laplacian arrangement gave the best fitting using the second force estimator while the best result obtained for the first force estimator is with the Right Diagonal Bipolar (DBR) arrangement combined with channel averaging. In future works, these force estimators, combined to HD-sEMG data fusion, will be experimentally evaluated.
Keywords
biomechanics; biomedical electrodes; electromyography; force measurement; medical signal processing; principal component analysis; sensor fusion; DBR; HD-sEMG data fusion; HD-sEMG grid signal; Laplacian arrangement; NRMSD; PCA; biomechanics; electrode arrangements; high-density SEMG grid; isometric contractions; monodimensional sEMG signal; muscle force estimation; muscular force; normalized RMS difference; right diagonal bipolar; sEMG-force generation model; sEMG-force relationship model; surface electromyography; Biological system modeling; Electrodes; Electromyography; Estimation; Force; Muscles; Principal component analysis; Data fusion; HD-sEMG; PCA; muscle force estimation; sEMG-Force relationship modeling;
fLanguage
English
Publisher
ieee
Conference_Titel
Advances in Biomedical Engineering (ICABME), 2013 2nd International Conference on
Conference_Location
Tripoli
Print_ISBN
978-1-4799-0249-1
Type
conf
DOI
10.1109/ICABME.2013.6648881
Filename
6648881