DocumentCode :
1959037
Title :
Experimental investigation of high voltage nanosecond generators of injection system for SIBERIA-2 storage ring
Author :
Kadnikov, Andrey ; Matveev, Yury
Author_Institution :
Russian Res. Center, Kurchatov Inst., Moscow, Russia
fYear :
1993
fDate :
17-20 May 1993
Firstpage :
1348
Abstract :
The injection system for SIBERIA-2 storage ring (Kurchatov Institute, Moscow) has been put into commissioning. The high voltage impulse generators with double coaxial forming lines and three-electrode nitrogen filled spark gaps are intended for linac electron gun and fast full-aperture kickers supply. The output impulses are up to 60 kV in amplitude, 15-20 ns in duration with front about 3 ns. A root-mean-square dispersion of time delay of gaps is 0.7-0.8 ns. The experimental results of operation of the generators are presented
Keywords :
beam handling techniques; electron accelerators; pulse generators; storage rings; 60 kV; SIBERIA-2 storage ring; double coaxial forming lines; fast full-aperture kickers supply; high voltage nanosecond generators; injection system; output impulses; three-electrode nitrogen filled spark gaps; time delay; Delay effects; Electrodes; Electrons; Linear particle accelerator; Nuclear power generation; Spark gaps; Stability; Storage rings; Thyratrons; Voltage;