DocumentCode :
1960744
Title :
A comparison between Sepic and Buck-Boost converters used in maximum power point trackers
Author :
Patarau, Toma ; Daraban, Stefan R. ; Petreus, Dorin ; Etz, Radu
Author_Institution :
Appl. Electron. Dept., Tech. Univ. of Cluj-Napoca, Cluj-Napoca, Romania
fYear :
2011
fDate :
11-15 May 2011
Firstpage :
397
Lastpage :
402
Abstract :
This paper presents a comparison between an analog compensated Sepic converter and a step down - step up converter (Buck-Boost) in a novel maximum power point tracking (MPPT) system. Both converters have advantages and disadvantages that will be pointed in this article. The algorithm that is used to provide the MPP for solar panels is Perturb and Observe (P&O) with three point weightings. Both simulations and practical results are analyzed and compared, afterwards conclusions are drawn.
Keywords :
maximum power point trackers; perturbation techniques; solar cells; MPP; MPPT system; analog compensated Sepic converter; buck-boost converter; maximum power point tracker; perturb and observe system; solar panel; step down converter; step up converter; three point weighting; Algorithm design and analysis; Inductors; Resistance; Seminars; Springs; Topology; Voltage control;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electronics Technology (ISSE), 2011 34th International Spring Seminar on
Conference_Location :
Tratanska Lomnica
ISSN :
2161-2528
Print_ISBN :
978-1-4577-2111-3
Type :
conf
DOI :
10.1109/ISSE.2011.6053895
Filename :
6053895
Link To Document :
بازگشت