DocumentCode :
1962437
Title :
An annular CMUT array beamforming system for high-frequency side looking IVUS imaging
Author :
Satir, Sarp ; Gurun, Gokce ; Zahorian, Jaime ; Karaman, Mustafa ; Hasler, Paul ; Degertekin, Levent
Author_Institution :
Sch. of Electr. & Comput. Eng., Georgia Inst. of Technol., Atlanta, GA, USA
fYear :
2010
fDate :
11-14 Oct. 2010
Firstpage :
563
Lastpage :
566
Abstract :
A CMUT annular array system for Side-Looking Intravascular Ultrasound (SL-IVUS) with fixed transmit and dynamic receive focusing capabilities has been developed. The system was experimentally characterized and validated through analytical models that simulate the beamformed transducer behavior. An 840 μm diameter, 35MHz array was fabricated, characterized, and used in experiments. The array consists of curved 18μm by 60μm CMUT membranes that form 8 ring transducer elements with approximately equal areas. The beamforming system uses an IC chip consisting of 8 transimpedance amplifiers and delay elements for receive beamforming with adjustable delays between 2ns and 4ns, that are constant up to 50 MHz with close to unity gain. Transmit focusing is implemented with an FPGA controlled, high voltage pulser board that can generate adjustable electrical pulses with delays as small as 2ns. The system is characterized by measuring the radiation patterns of individual CMUT annular array elements as well as the unfocused and fixed transmit focused arrays. The results show predicted behavior including acoustic crosstalk effects at certain frequencies. For transmit-receive beamforming characterization, a 25μm gold wire was imaged using 4 beamformed transmit elements and 4 beamformed receive elements with different delay values. The results show improved lateral resolution and lower side lobes with proper beamforming.
Keywords :
bioMEMS; biomedical transducers; biomedical ultrasonics; blood vessels; capacitive sensors; microsensors; ultrasonic transducer arrays; CMUT membrane; IC chip; acoustic crosstalk effect; annular CMUT array beamforming system; capacitive micromachined ultrasonic transducer; delay element; electrical pulse; high frequency side looking IVUS imaging; intravascular ultrasound; transimpedance amplifier; transmit receive beamforming; Acoustics; Array signal processing; Arrays; Delay; Integrated circuits; Pistons; Probes; CMUTs; Side Looking Intravascular Ultrasound; annular arrays; beamforming;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Ultrasonics Symposium (IUS), 2010 IEEE
Conference_Location :
San Diego, CA
ISSN :
1948-5719
Print_ISBN :
978-1-4577-0382-9
Type :
conf
DOI :
10.1109/ULTSYM.2010.5935937
Filename :
5935937
Link To Document :
بازگشت