DocumentCode :
1962776
Title :
Comparison of two Strontium optical lattice clocks in agreement at the 10−16 level
Author :
Le Targat, Rodolphe ; Lorini, Luca ; Gurov, M. ; Zawada, Michal ; Gartman, Rafal ; Nagorny, Bartlomiej ; Lemonde, P. ; Lodewyck, Jerome
Author_Institution :
LNE-SYRTE, Obs. de Paris, UPMC, Paris, France
fYear :
2012
fDate :
23-27 April 2012
Firstpage :
19
Lastpage :
22
Abstract :
Two optical lattice clocks operated on the transition 1S0-3P0 of the 87Sr atom are now operational at the LNE-SYRTE laboratory, their comparison aims at demonstrating that no systematic effect has been overlooked in their respective accuracy budgets. In this proceeding we focus only on trapping effects, we discuss technical aspects of the calibration of the lattice induced light shifts, and we show the observation of the second order light shift. Data resulting from the comparisons are reported and discussed.
Keywords :
calibration; optical lattices; strontium; LNE-SYRTE laboratory; Sr; calibration; lattice induced light shift; optical lattice clock; second order light shift; systematic effect; trapping effect;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
European Frequency and Time Forum (EFTF), 2012
Conference_Location :
Gothenburg
Print_ISBN :
978-1-4673-1924-9
Type :
conf
DOI :
10.1109/EFTF.2012.6502324
Filename :
6502324
Link To Document :
بازگشت