Title :
Commissioning of the SIBERIA-2 preinjector and first beam results
Author :
Korchuganov, V. ; Kulipanov, G. ; Levichev, E. ; Nezhevenko, O. ; Ostreiko, G. ; Philipchenko, A. ; Serdobintsev, G. ; Shairmerdenov, E. ; Ushakov, V. ; Kadnikov, A. ; Krylov, Yu. ; Kuznetsov, S. ; Ushkov, V. ; Yupinov, Yu.
Author_Institution :
Inst. of Nucl. Phys., Novosibirsk, Russia
Abstract :
The DAW structure linac-the preinjector for the SIBERIA SR complex was commissioned on November 1, 1992 when the 62.5 MeV electron beam is obtained. A 6-m-long high impedance (92 MOhm/m) linac operates at 2.8 GHz. The paper describes the experimental RF characteristics of the linac structure and beam measurements obtained during the commissioning. The results of electron current, energy spectrum, beam profiles and emittance measurements are presented
Keywords :
beam handling techniques; electron accelerators; linear accelerators; particle beam diagnostics; storage rings; 2.8 GHz; 6 m; 62.5 MeV; DAW structure linac; RF characteristics; SIBERIA synchrotron radiation complex; SIBERIA-2 preinjector; beam measurements; beam profiles; commissioning; electron beam; electron current; emittance measurements; energy spectrum; high impedance linac; Acceleration; Ceramics; Electron beams; Impedance; Klystrons; Linear particle accelerator; Radio frequency; Strontium; Vacuum breakdown; Voltage;
Conference_Titel :
Particle Accelerator Conference, 1993., Proceedings of the 1993
Conference_Location :
Washington, DC
Print_ISBN :
0-7803-1203-1
DOI :
10.1109/PAC.1993.308851