• DocumentCode
    1964265
  • Title

    Influence of the ionization loss in the diagnostic foil on the phase motion in the phasotron

  • Author

    Borisov, O.N. ; Onischenko, L.M.

  • Author_Institution
    JINR, Dubna, Russia
  • fYear
    1993
  • fDate
    17-20 May 1993
  • Firstpage
    518
  • Abstract
    In the present paper it is shown that the influence of the ionization loss in the foil on the longitudinal motion consists of the synchronous phase shift followed by the phase oscillation amplitude compression
  • Keywords
    energy loss of particles; ion accelerators; particle beam diagnostics; synchrotrons; JINR phasotron; diagnostic foil; ionization loss; longitudinal motion; phase motion; phase oscillation amplitude compression; synchronous phase shift; Acceleration; Aluminum; Energy loss; Equations; Frequency; Ionization; Numerical analysis; Particle beams; Stability; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1993., Proceedings of the 1993
  • Conference_Location
    Washington, DC
  • Print_ISBN
    0-7803-1203-1
  • Type

    conf

  • DOI
    10.1109/PAC.1993.308864
  • Filename
    308864