DocumentCode
1965373
Title
Correction schemes to improve the dynamical aperture of the Main Injector
Author
Mishra, C.S. ; Haroush, F.A.
Author_Institution
Fermi Nat. Accel. Lab., Batavia, IL, USA
fYear
1993
fDate
17-20 May 1993
Firstpage
348
Abstract
Tracking simulations have revealed that the dominant factor limiting the dynamical aperture of the Main Injector are the large octupole component and the random errors in the recycled Main Ring quadrupoles. This paper describes a correction scheme that reduces the effect of these errors on the performance of the Fermilab Main Injector, specially for the slow extraction operation
Keywords
beam handling techniques; proton accelerators; synchrotrons; Fermilab Main Injector; dynamical aperture correction schemes; large octupole component; recycled Main Ring quadrupole random errors; slow extraction operation; Apertures; Error correction; Extraterrestrial measurements; Laboratories; Lattices; Magnetic field measurement; Magnetic fields; Magnets; Production; Radio frequency;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 1993., Proceedings of the 1993
Conference_Location
Washington, DC
Print_ISBN
0-7803-1203-1
Type
conf
DOI
10.1109/PAC.1993.308917
Filename
308917
Link To Document