• DocumentCode
    1965593
  • Title

    An ECG-on-Chip for Wearable Cardiac Monitoring Devices

  • Author

    Deepu, C.J. ; Xu, X.Y. ; Zou, X.D. ; Yao, L.B. ; Lian, Y.

  • Author_Institution
    Dept. of Electr. & Comput. Eng., Nat. Univ. of Singapore, Singapore, Singapore
  • fYear
    2010
  • fDate
    13-15 Jan. 2010
  • Firstpage
    225
  • Lastpage
    228
  • Abstract
    This paper describes a highly integrated, low power chip solution for ECG signal processing in wearable devices. The chip contains an instrumentation amplifier with programmable gain, a band-pass filter, a 12-bit SAR ADC, a novel QRS detector, 8 K on-chip SRAM, and relevant control circuitry and CPU interfaces. The analog front end circuits accurately senses and digitizes the raw ECG signal, which is then filtered to extract the QRS. The sampling frequency used is 256 Hz. ECG samples are buffered locally on an asynchronous FIFO and is read out using a faster clock, as and when it is required by the host CPU via an SPI interface. The chip was designed and implemented in 0.35 ¿m standard CMOS process. The analog core operates at 1 V while the digital circuits and SRAM operate at 3.3 V. The chip total core area is 5.74 mm2 and consumes 9.6 ¿W. Small size and low power consumption make this design suitable for usage in wearable heart monitoring devices.
  • Keywords
    CMOS integrated circuits; SRAM chips; amplifiers; analogue-digital conversion; band-pass filters; biomedical electronics; biomedical equipment; electrocardiography; low-power electronics; medical signal processing; patient monitoring; system-on-chip; CMOS process; CPU interfaces; ECG signal processing; ECG-on-chip; QRS detector; SAR ADC; SRAM; analog front end circuits; asynchronous FIFO; band-pass filter; control circuitry; digital circuits; frequency 256 Hz; instrumentation amplifier; low power chip solution; low power consumption; on-chip SRAM; power 9.6 muW; programmable gain; size 0.35 mum; temperature 8 K; voltage 1 V; voltage 3.3 V; wearable cardiac monitoring devices; wearable heart monitoring devices; Band pass filters; Biomedical monitoring; Central Processing Unit; Circuits; Detectors; Electrocardiography; Instruments; Random access memory; Signal processing; Signal sampling; ECG-on-Chip; Electrocardiography; Low Power design; QRS detection; Wearable devices;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electronic Design, Test and Application, 2010. DELTA '10. Fifth IEEE International Symposium on
  • Conference_Location
    Ho Chi Minh City
  • Print_ISBN
    978-0-7695-3978-2
  • Electronic_ISBN
    978-1-4244-6026-7
  • Type

    conf

  • DOI
    10.1109/DELTA.2010.43
  • Filename
    5438685