  • Abstract
    We designed a compact electron storage ring system which gives an X-ray photon density of 1010 photons/mm2/sec at 33 keV for the K-edge subtraction method using a two-dimensional imaging system. We adopted a beam energy of 1.75 GeV, a maximum field for the superconducting wigglers of 8.3 Tesla, a stored current higher than 800 mA and a low energy injection system. A ring system with a circumference of about 60 m is feasible
  • Keywords
    X-ray production; biomedical equipment; cardiology; diagnostic radiography; electron accelerators; storage rings; 1.75 GeV; 33 keV; 8.3 T; X-ray; coronary angiography; electron storage ring; injection system; superconducting wigglers; two-dimensional imaging; Angiography; Digital images; Electrons; Optical imaging; Pixel; Production facilities; Storage rings; Strontium; Undulators; X-ray imaging;