Abstract :
From a systematic analysis of readings of the beam position monitors in the AGS Booster ring, combined with the transfer matrices between a few locations in the ring, calculated with MAD, the consistency of the model of the lattice has been tested. This technique has enabled us to (i) detect errors in the machine that subsequent survey during shutdown has confirmed, and (ii) to measure the actual circulating beam momentum offset. The method has proved rather general and convenient for accelerator diagnostics as part of a model-based accelerator control system and extensions are suggested
Keywords :
matrix algebra; particle beam diagnostics; physical instrumentation control; proton accelerators; synchrotrons; AGS Booster; MAD; accelerator diagnostics; beam position monitors; circulating beam momentum offset; consistency test; lattice; model-based accelerator control system; ring diagnostics; shutdown; systematic analysis; transfer matrices; Clocks; Control system synthesis; Data mining; Extraterrestrial measurements; Laboratories; Lattices; Measurement errors; Orbital calculations; System testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Particle Accelerator Conference, 1993., Proceedings of the 1993
Conference_Location :
Washington, DC
Print_ISBN :
0-7803-1203-1
Type :
conf
DOI :
10.1109/PAC.1993.309160
Filename :
309160
Link To Document :
بازگشت