DocumentCode
1971645
Title
Beam instrumentation for the SSC RFQ
Author
Datte, P. ; Jamieson, G. ; Aiello, R. ; Beechy, D. ; Jones, A. ; Martin, D. ; Riordon, J. ; Webber, R. ; Wood, F.
Author_Institution
Superconducting Super Collider Lab., Dallas, TX, USA
fYear
1993
fDate
17-20 May 1993
Firstpage
2118
Abstract
A detailed description of the SSC RFQ beam instrumentation is presented. Most of the instrumentation is located in the RFQ end walls. The upstream end wall contains a segmented Faraday cup, a segmented aperture and a wire scanner. The down stream end wall contains a segmented aperture and wire scanner. Two current toroids are used to measure the transmission through the RFQ. The output of the RFQ is a low emittance, pulsed 2.5 MeV H- beam with peak current of 25 mA and maximum pulse length of 35 μs. Typical beam data are shown with the emphasis being on instrumentation performance
Keywords
beam handling equipment; particle beam diagnostics; 2.5 MeV; 35 mus; H- beam; RFQ; SSC; beam instrumentation; current toroids; emittance; pulse length; segmented Faraday cup; segmented aperture; wire scanner; Apertures; Colliding beam devices; Current measurement; Electric variables measurement; Instruments; Laboratories; Monitoring; Position measurement; Size measurement; Superconducting filaments and wires;