DocumentCode :
1972151
Title :
Abort interlock diagnostic for protection of APS vacuum chamber
Author :
Decker, Glenn
Author_Institution :
Advanced Photon Source, Argonne Nat. Lab., IL, USA
fYear :
1993
fDate :
17-20 May 1993
Firstpage :
2196
Abstract :
The Advanced Photon Source (APS) vacuum system has been designed to be passively safe from bending magnet radiation heating at positron beam currents up to 30 mA. Above this value, certain components may be damaged from vertical beam missteering, although work is proceeding to raise the safe current threshold. Because of this, a system for preventing the misalignment of high power density beams is required. This report details a system for protection from dipole radiation only. Work on a system for ID radiation is continuing
Keywords :
electron accelerators; particle beam diagnostics; storage rings; 30 mA; APS vacuum chamber; Advanced Photon Source vacuum system; ID radiation; abort interlock diagnostic; bending magnet radiation heating; dipole radiation; high power density beam misalignment; positron beam currents; safe current threshold; vertical beam missteering; Apertures; Bellows; Fans; Gaussian distribution; Government; Heating; Positrons; Protection; Storage rings; Vacuum systems;