• DocumentCode
    1972151
  • Title

    Abort interlock diagnostic for protection of APS vacuum chamber

  • Author

    Decker, Glenn

  • Author_Institution
    Advanced Photon Source, Argonne Nat. Lab., IL, USA
  • fYear
    1993
  • fDate
    17-20 May 1993
  • Firstpage
    2196
  • Abstract
    The Advanced Photon Source (APS) vacuum system has been designed to be passively safe from bending magnet radiation heating at positron beam currents up to 30 mA. Above this value, certain components may be damaged from vertical beam missteering, although work is proceeding to raise the safe current threshold. Because of this, a system for preventing the misalignment of high power density beams is required. This report details a system for protection from dipole radiation only. Work on a system for ID radiation is continuing
  • Keywords
    electron accelerators; particle beam diagnostics; storage rings; 30 mA; APS vacuum chamber; Advanced Photon Source vacuum system; ID radiation; abort interlock diagnostic; bending magnet radiation heating; dipole radiation; high power density beam misalignment; positron beam currents; safe current threshold; vertical beam missteering; Apertures; Bellows; Fans; Gaussian distribution; Government; Heating; Positrons; Protection; Storage rings; Vacuum systems;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1993., Proceedings of the 1993
  • Conference_Location
    Washington, DC
  • Print_ISBN
    0-7803-1203-1
  • Type

    conf

  • DOI
    10.1109/PAC.1993.309266
  • Filename
    309266