• DocumentCode
    1973038
  • Title

    RF beam position monitors for the TESLA Test Facility

  • Author

    Lorenz, Ronald

  • Author_Institution
    Tech. Univ. Berlin, Germany
  • fYear
    1993
  • fDate
    17-20 May 1993
  • Firstpage
    2325
  • Abstract
    For the TESLA Test Facility beam position monitors with a precision of about 10 μm are required. A circular cavity excited in the TM110-mode by the off-axis beam provides a signal strong enough for various injectors. Expected signal to noise ratios and the theoretical resolution are estimated for a designed structure. A coaxial combiner was designed for common mode rejection. It is also foreseen to test different low-impedance monitors behind the injector. A structure using two coupled cavities is briefly described
  • Keywords
    beam handling techniques; cavity resonators; cyclotrons; particle beam diagnostics; position measurement; proton accelerators; RF beam position monitors; TESLA Test Facility; TM110-mode; circular cavity; coaxial combiner; common mode rejection; coupled cavities; injectors; low-impedance monitors; off-axis beam; signal to noise ratios; Acceleration; Circuit noise; Coaxial components; Electromagnetic interference; Impedance; Radio frequency; Resonant frequency; Signal resolution; Testing; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1993., Proceedings of the 1993
  • Conference_Location
    Washington, DC
  • Print_ISBN
    0-7803-1203-1
  • Type

    conf

  • DOI
    10.1109/PAC.1993.309310
  • Filename
    309310