• DocumentCode
    1973108
  • Title

    Design and calibration of pickup-electrodes for beam position monitoring at SOR-RING

  • Author

    Shinoe, Kenji ; Nakamura, Norio ; Katsura, Tomotaro ; Kamiya, Yushi

  • Author_Institution
    Inst. for Solid State Phys., Tokyo Univ., Japan
  • fYear
    1993
  • fDate
    17-20 May 1993
  • Firstpage
    2337
  • Abstract
    Described in this paper are the design and calibration of button-type pickup-electrodes, which have been incorporated in the beam position monitoring system (BPM system) at SOR-RING. The BPM system that has been developed as an R&D for a third-generation VUV synchrotron light source is aimed at testing the key components of the system, PIN diode switches. This system is also aimed at measuring the beam position of SOR-RING and correcting it. In addition, briefly described in the paper are ion-clearing electrodes installed in the ring
  • Keywords
    beam handling techniques; calibration; electron accelerators; nuclear electronics; p-i-n diodes; particle beam diagnostics; position measurement; semiconductor switches; storage rings; PIN diode switches; SOR-RING; beam position correction; beam position monitoring; button-type electrodes; calibration; ion-clearing electrodes; pickup-electrodes; third-generation VUV synchrotron light source; Calibration; Capacitance; Electrodes; Extraterrestrial measurements; Monitoring; Solid state circuits; Structural beams; Switches; Testing; Welding;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1993., Proceedings of the 1993
  • Conference_Location
    Washington, DC
  • Print_ISBN
    0-7803-1203-1
  • Type

    conf

  • DOI
    10.1109/PAC.1993.309314
  • Filename
    309314