Abstract
Described in this paper are the design and calibration of button-type pickup-electrodes, which have been incorporated in the beam position monitoring system (BPM system) at SOR-RING. The BPM system that has been developed as an R&D for a third-generation VUV synchrotron light source is aimed at testing the key components of the system, PIN diode switches. This system is also aimed at measuring the beam position of SOR-RING and correcting it. In addition, briefly described in the paper are ion-clearing electrodes installed in the ring
Keywords
beam handling techniques; calibration; electron accelerators; nuclear electronics; p-i-n diodes; particle beam diagnostics; position measurement; semiconductor switches; storage rings; PIN diode switches; SOR-RING; beam position correction; beam position monitoring; button-type electrodes; calibration; ion-clearing electrodes; pickup-electrodes; third-generation VUV synchrotron light source; Calibration; Capacitance; Electrodes; Extraterrestrial measurements; Monitoring; Solid state circuits; Structural beams; Switches; Testing; Welding;