Abstract
The principle of the ionization spot size monitor built at Orsay and installed at the focal point of the FFTB line of SLAC is reviewed. Its constituents (pulsed gas target, MCP ion detector and electronics) and their performances are briefly described, together with preliminary background tests performed at Orsay
Keywords
electron accelerators; electron optics; focusing; linear accelerators; nuclear electronics; particle beam diagnostics; FFTB line; Final Focus Test Beam; MCP ion detector; Orsay spot size monitor; SLAC; electronics; focal point; ionization spot size monitor; preliminary background tests; pulsed gas target; Argon; Charge measurement; Current measurement; Electric variables measurement; Helium; Monitoring; Size measurement; Space charge; Strips; Testing;