DocumentCode
197510
Title
Efectos del cortocircuito entre espiras en máquinas síncronas de imanes permanentes
Author
Mazzoletti, Manuel A. ; Bossio, Guillermo R. ; De Angelo, Cristian H. ; Espinoza-Trejo, Diego R.
Author_Institution
Grupo de Electrónica Aplicada (GEA), Facultad de Ingeniería, UNRC, Ruta Nacional #36, km #601, X5804BYA, Río Cuarto, Córdoba - Argentina
fYear
2014
fDate
11-13 June 2014
Firstpage
531
Lastpage
536
Abstract
The effects of stator winding interturn short-circuit faults in Permanent Magnet Synchronous Motors (PMSM) are analyzed in this paper. A dynamic model with stator winding interturn faults is evaluated. This model allows to generate the interturn short-circuit through a severity factor vector fault for any phase. Aiming to develop strategies for detection, analysis of the effects of this type of fault experimentally supplemented with laboratory results. For this purpose the stator winding of PMSM was modified, allowing to generate the fault in one of the phases.
fLanguage
English
Publisher
ieee
Conference_Titel
Biennial Congress of Argentina (ARGENCON), 2014 IEEE
Conference_Location
Bariloche, Argentina
Print_ISBN
978-1-4799-4270-1
Type
conf
DOI
10.1109/ARGENCON.2014.6868547
Filename
6868547
Link To Document