Abstract :
A sextupole magnet has been designed to satisfy the dynamical, geometrical, and electrical requirements of the Fermilab Main Injector. The steel length is 0.457 m. The top and bottom pole tips are 26.4 mm from the center line. the side pole tips are 48.0 mm from the center line. The design integrated strength is 55 T-m/m2 at 294 A
Keywords :
beam handling equipment; beam handling techniques; electromagnets; proton accelerators; synchrotrons; 0.457 m; 294 A; Fermilab Main Injector; bottom pole tip; center line; design integrated strength; dynamical requirements; electrical requirements; geometrical requirements; proton synchrotron; sextupole magnet; side pole tips; steel length; top pole tip; Circuit testing; Coils; Conducting materials; Cooling; Costs; Inductance; Laboratories; Magnets; Power supplies; Steel;