Final results of magnetic measurements of 128 quadrupoles and 32 sextupoles are presented. There are many places in the SHR complex where these magnets will be operated from a common power supply. For the quadrupole magnets there are 4 octets, 4 triplets and 18 doublets; these magnets have been matched to ±0.1% in excitation response for the operating range corresponding to 0.3-1.0 GeV. For the sextupoles there are four octets where the (pairwise) matching has generally been made to the ±0.3% level. Parameterization of the data as well as fits are described and examples of the magnet groupings are shown
Keywords
beam handling equipment; magnetic field measurement; storage rings; MIT-Bates South Hall Ring; doublets; excitation response; magnet groupings; magnetic measurements; octets; quadrupole magnets; sextupole magnets; triplets; Coils; Data mining; Geometry; Harmonic analysis; Linear accelerators; Magnetic analysis; Magnetic variables measurement; Magnets; Power supplies; Q measurement;