• DocumentCode
    1978088
  • Title

    Parametric studies with PARMELA to improve SLC performance

  • Author

    Jones, T.A. ; Yeremian, A.D. ; Miller, R.H.

  • Author_Institution
    Stanford Linear Accel. Center, Stanford Univ., CA, USA
  • fYear
    1993
  • fDate
    17-20 May 1993
  • Firstpage
    3063
  • Abstract
    The PARMELA particle dynamics code has been used at SLAC to simulate the SLC injector from the electron gun through the first accelerator section. The strength of injector components was set and tuned based on the simulation results. Parametric studies with PARMELA were conducted in which injector components were varied in an incremental fashion to study their effects on beam parameters such as current transmission, capture of the charge in 20° of the S-Band, required for a satisfactory spectrum, and the emittance. We discuss the results of our simulation and its application to optimizing the performance of the injector
  • Keywords
    electron accelerators; electron guns; linear accelerators; particle beam diagnostics; physics computing; PARMELA code; S-Band; SLC injector; beam parameters; charge capture; current transmission; electron gun; emittance; parametric studies; Acceleration; Damping; Electrons; Energy capture; Linear accelerators; Monitoring; Particle accelerators; Particle beams; Phasor measurement units; Stability;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1993., Proceedings of the 1993
  • Conference_Location
    Washington, DC
  • Print_ISBN
    0-7803-1203-1
  • Type

    conf

  • DOI
    10.1109/PAC.1993.309553
  • Filename
    309553