DocumentCode
1979148
Title
Initial operation and beam characteristics of the UCLA S-band RF photo-injector
Author
Pellegrini, C. ; Barov, N. ; Hartman, S.C. ; Park, S. ; Rosenzweig, J. ; Travish, G. ; Zhang, R. ; Davis, P. ; Joshi, C. ; Hairapetian, G.
Author_Institution
Dept. of Phys., California Univ., Los Angeles, CA, USA
fYear
1993
fDate
17-20 May 1993
Firstpage
3216
Abstract
The UCLA RF photo-injector system has been commissioned. All of the sub-components such as the high power RF, pico-second laser, RF photo-injector cavity, diagnostics, and supporting hardware have been tested and are operational. We briefly discuss the performance of the various components since the details of each subsystem are very lengthy. The laser delivers a sub 4 ps pulse containing 0-300 μJ of energy per pulse. The photo-injector produces 0-3 nC per bunch with an RF induced emittance of 1.5 π(mm-mrad)
Keywords
beam handling techniques; cavity resonators; particle beam diagnostics; 0 J to 300 muJ; 4 ps; RF photo-injector cavity; S-band; UCLA RF photo-injector; diagnostics; emittance; high power RF; pico-second laser; Cathodes; Electron beams; Electron sources; Fiber lasers; Klystrons; Laser mode locking; Optical pulses; Particle beams; Pulse amplifiers; Radio frequency;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 1993., Proceedings of the 1993
Conference_Location
Washington, DC
Print_ISBN
0-7803-1203-1
Type
conf
DOI
10.1109/PAC.1993.309606
Filename
309606
Link To Document