DocumentCode :
1979582
Title :
Time comparison of atomic clocks using counter and GPS system
Author :
Gamidov, R. ; Cetintas, Mustafa
Author_Institution :
Tubitak, Gebze-Kocaeli, Turkey
Volume :
1
fYear :
1999
fDate :
1999
Firstpage :
268
Abstract :
Two HP 5071A Cs atomic clocks were used as a reference to AOA GPS receivers TTRSA and TTR6 respectively. At the same time interval, these reference atomic clocks were compared using both GPS common view method (CVM) and time interval counter (TIG). The time differences between the atomic clocks were analyzed and compared in two types of measurement technique
Keywords :
Global Positioning System; atomic clocks; calibration; measurement standards; radio receivers; AOA GPS receivers; Cs; GPS common view method; HP 5071A Cs atomic clocks; TTR6; TTRSA; counter; reference atomic clocks; time interval; time interval counter; Antenna measurements; Atomic clocks; Counting circuits; Erbium; Fluctuations; Global Positioning System; Receiving antennas; Satellites; Temperature sensors; Time measurement;