DocumentCode
1980214
Title
Impedance of a small-gap undulator vacuum chamber
Author
Bane, K. ; Krinsky, S.
Author_Institution
Linear Accel. Center, Stanford Univ., CA, USA
fYear
1993
fDate
17-20 May 1993
Firstpage
3375
Abstract
Insertion device performance is limited by the minimum magnet gap allowed by storage ring beam dynamics. In this note, we analyze the impedance of the vacuum chamber for the prototype small-gap undulator being built for the NSLS X-ray ring, and discuss the consequent beam instability thresholds
Keywords
beam handling techniques; electric impedance; electron accelerators; particle beam diagnostics; storage rings; vacuum apparatus; wigglers; NSLS X-ray ring; beam instability thresholds; insertion device performance; small-gap undulator; storage ring beam dynamics; vacuum chamber; Apertures; Damping; Electron beams; Impedance; Magnetic devices; Power dissipation; Prototypes; Stability; Structural beams; Undulators;
fLanguage
English
Publisher
ieee
Conference_Titel
Particle Accelerator Conference, 1993., Proceedings of the 1993
Conference_Location
Washington, DC
Print_ISBN
0-7803-1203-1
Type
conf
DOI
10.1109/PAC.1993.309655
Filename
309655
Link To Document