• DocumentCode
    19817
  • Title

    Edge localisation in MRI for images with signal-dependent noise

  • Author

    Aarya, I. ; Jiang, D. ; Gale, T.

  • Author_Institution
    Sch. of Eng. & ICT, Univ. of Tasmania, Hobart, TAS, Australia
  • Volume
    51
  • Issue
    15
  • fYear
    2015
  • fDate
    7 23 2015
  • Firstpage
    1151
  • Lastpage
    1153
  • Abstract
    A new edge localisation technique for step edges in images with signal-dependent Rician noise in MRI is proposed. Dependent noise can not only affect the detection of true edges in an image but also their position. Inaccurate localisation of an edge can lead to insufficient segmentation and reduce the overall accuracy of any edge detection method. The proposed technique uses higher-order moments of the noise function to determine the correction factor for localisation and thus reduce the overall mean square error for true edge localisation due to noise. The proposed technique offers significant improvement in edge localisation for an image as compared with Canny and Sobel methods.
  • Keywords
    biomedical MRI; edge detection; mean square error methods; medical image processing; Canny methods; MRI; MSE; Sobel methods; correction factor; edge detection method; edge localisation technique; magnetic resonance imaging; mean square error; noise function; signal dependent Rician noise; signal dependent noise;
  • fLanguage
    English
  • Journal_Title
    Electronics Letters
  • Publisher
    iet
  • ISSN
    0013-5194
  • Type

    jour

  • DOI
    10.1049/el.2015.0774
  • Filename
    7163391