Title :
Starting study of DC inverter compressor
Author_Institution :
Electron. & Inf. Coll., Yangtze Univ., Jingzhou, China
Abstract :
With DC inverter compressors starting characteristics, the three-step starting method was used. The role of 3-steps and the transition in them was researched, the control method of preposition phase and forced synchronous phase is proposed. Focusing on the step time control law of forced synchronous phase in variable load startup, the step time control method is obtained and the research results is confirmed by prototype test.
Keywords :
compressors; invertors; phase control; position control; DC inverter compressor; forced synchronous phase; forced synchronous phase control method; preposition phase control method; step time control law; three-step starting method; variable load startup; Brushless DC motors; Commutation; Educational institutions; Focusing; Integrated circuits; Inverters; World Wide Web; 3-step; BLDC; DC inverter compressor; startup;
Conference_Titel :
Electrical and Control Engineering (ICECE), 2011 International Conference on
Conference_Location :
Yichang
Print_ISBN :
978-1-4244-8162-0
DOI :
10.1109/ICECENG.2011.6057720