DocumentCode :
1991192
Title :
A Self-Calibration Technique for Dual Six-Port Network Analyzers
Author :
Malkomes, M. ; Meyer, R.
Author_Institution :
Institut fÿr Hochfrequenztechnik, RWTH Aachen, Melatener StraÃ\x9fe 25, D-5100 Aachen, West Germany
fYear :
1984
fDate :
10-13 Sept. 1984
Firstpage :
796
Lastpage :
800
Abstract :
A simple calibration technique for use in dual six-port automatic network analyzers is presented. The calibration of each six-port with four standards (sliding load, short, two offset shorts) is combined with a "thru" self-calibration technique, which determines the scattering characteristics of the sixport measurement setup. An error correction procedure is used, eliminating the need of ideal six-ports for high precision measurements.
Keywords :
Calibration; Computer errors; Computer simulation; Detectors; Error correction; Measurement errors; Measurement standards; Reflection; Standards development; Switches;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Microwave Conference, 1984. 14th European
Conference_Location :
Liege, Belgium
Type :
conf
DOI :
10.1109/EUMA.1984.333447
Filename :
4132129
Link To Document :