• DocumentCode
    1991820
  • Title

    Quantitative comparison of scattering coefficient with ultrahigh resolution optical coherence tomography

  • Author

    Ishida, Shutaro ; Nishizawa, Norihiko

  • Author_Institution
    Dept. of Electr. Eng. & Comput. Sci., Nagoya Univ., Nagoya, Japan
  • fYear
    2011
  • fDate
    Aug. 28 2011-Sept. 1 2011
  • Firstpage
    778
  • Lastpage
    780
  • Abstract
    Realization of ultrahigh resolution and deeper imaging is one of key problems in OCT. We have quantitatively confirmed the improvement of imaging depth in 1700 nm ultrahigh resolution OCT compared with the other wavelength regions.
  • Keywords
    biomedical optical imaging; image resolution; optical tomography; imaging depth; optical coherence tomography; scattering coefficient; ultrahigh resolution; wavelength 1700 nm; Fiber nonlinear optics; Image resolution; Optical fibers; Optical imaging; Optical scattering;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Quantum Electronics Conference & Lasers and Electro-Optics (CLEO/IQEC/PACIFIC RIM), 2011
  • Conference_Location
    Sydney, NSW
  • Print_ISBN
    978-1-4577-1939-4
  • Type

    conf

  • DOI
    10.1109/IQEC-CLEO.2011.6194022
  • Filename
    6194022