• DocumentCode
    1992597
  • Title

    Recent proton and Co60 radiation test data from a newly developed European optocoupler source for space application

  • Author

    Bregoli, M. ; Hernandez, S. ; Ress, C. ; Collini, A. ; Ficorella, F. ; How, L.S. ; Costantino, Alessandra ; Ferlet-Cavrois, Veronique ; Zahir, M.

  • Author_Institution
    Optoelettronica Italia Srl, Gardolo, Italy
  • fYear
    2013
  • fDate
    23-27 Sept. 2013
  • Firstpage
    1
  • Lastpage
    5
  • Abstract
    The permanent degradation introduced in the main electrical parameters of a newly developed European optocoupler type is described, as a function of proton fluences and Co-60 total ionizing dose. Optoi´s devices assembled in Leadless Chip Carrier packages, coded OIER10 are being developed in the framework of an ECI project for ESA, aimed at the ESCC evaluation of Optoi optocouplers. The first analyses of the recent irradiation results show a good behavior of the parts under proton and gamma irradiation.
  • Keywords
    cobalt; integrated circuit packaging; proton effects; space vehicle electronics; 60Co; European optocoupler source; OIER10 code; leadless chip carrier packages; proton fluences; proton test data; radiation test data; space application; total ionizing dose; Degradation; Europe; Light emitting diodes; Phototransistors; Protons; Radiation effects; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Radiation and Its Effects on Components and Systems (RADECS), 2013 14th European Conference on
  • Conference_Location
    Oxford
  • Type

    conf

  • DOI
    10.1109/RADECS.2013.6937401
  • Filename
    6937401