DocumentCode :
1992780
Title :
Energy Saving Analysis in the Cold End System of Existing 300MW Turbine with Heat Pumps for Heating
Author :
Chang, Shuping ; Sun, Ke ; Zhang, Shufang ; Guo, Jianglong
Author_Institution :
Thermal Dynamic Technol. Inst., Hebei Electr. Power Res. Inst., Shijiazhuang, China
fYear :
2012
fDate :
27-30 May 2012
Firstpage :
1
Lastpage :
3
Abstract :
This article is according to the actual situation of two units of 300MW turbine generator and 9sets of heating pumps combined heating thermal plant analyze and calculate the turbine cold end system energy saving effect. From the analyzing, after the thermal plant increased the heat pump, the heating supply increased 351.7021GJ/h, the heating areas increased 1953.89 thousand square meters, save the circulating water quantity 72t/h, energy utilize efficiency increased 8.01%. From the data, we can know that the new power and heat cogeneration mode using the thermal plant circulating water system as heat pump hot end have conspicuous energy saving effects.
Keywords :
AC generators; cogeneration; energy conservation; heat pumps; pumping plants; combined heating thermal plant; efficiency 8.01 percent; energy saving analysis; heat cogeneration mode; heat pumps; power 300 MW; thermal plant circulating water system; turbine cold end system; turbine generator; Absorption; Cogeneration; Cooling; Heat pumps; Water heating; Water resources;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering and Technology (S-CET), 2012 Spring Congress on
Conference_Location :
Xian
Print_ISBN :
978-1-4577-1965-3
Type :
conf
DOI :
10.1109/SCET.2012.6342139
Filename :
6342139
Link To Document :
بازگشت