• DocumentCode
    1993631
  • Title

    Research on the temperature hydraulic model of the large steam generator stator windings

  • Author

    Heming, Li ; Yonggang, Li ; Junqing, Li

  • Author_Institution
    North China Electr. Power Univ., China
  • Volume
    1
  • fYear
    2001
  • fDate
    2001
  • Firstpage
    160
  • Abstract
    With the analysis of heat and temperature-transfer in generator stator windings, the temperature hydraulic model of large steam generator stator windings is found. That is the calculation method for copper temperature and the temperature of water outlet (standard temperature) in steam generator stator windings on the normal running condition (no-fault and well-running condition), which is verified by many kinds of working condition data
  • Keywords
    fault diagnosis; stators; thermal analysis; turbogenerators; copper temperature; generator stator windings; heat fault mechanism; heat transfer; no-fault condition; normal running condition; stator over-temperature; steam generator stator windings; temperature hydraulic model; temperature transfer; water outlet temperature; water-cooling; well-running condition; working condition data; Circuit faults; Conductors; Cooling; Copper; Inductors; Power generation; Stator windings; Temperature measurement; Water heating; Wire;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Machines and Systems, 2001. ICEMS 2001. Proceedings of the Fifth International Conference on
  • Conference_Location
    Shenyang
  • Print_ISBN
    7-5062-5115-9
  • Type

    conf

  • DOI
    10.1109/ICEMS.2001.970633
  • Filename
    970633