DocumentCode :
1994524
Title :
Novel on-line partial discharge monitoring system for generator/motor stator insulations
Author :
Kim, Yong-Joo ; Hwang, Don-Ha ; Park, Doh-Young ; Song, Sang-Ock
Author_Institution :
Mechatronics Res. Group, Korea Electrotechnol. Res. Inst., Changwon, South Korea
Volume :
1
fYear :
2001
fDate :
2001
Firstpage :
330
Abstract :
Nowadays on-line monitoring scheme with trending technique is widely adopted in insulation diagnosis. In this paper, two types of online monitoring instrumentation for an insulation diagnosis are proposed. The first unit obtains the parameters such as partial discharge magnitude and dynamic stagnation voltage (DSV) in selected frequency bands. The partial discharge activities can be interpreted more precisely by these techniques. The second one indicates the partial discharge spectra in reduced time resolution with lower cost. Several online sensors for partial discharges monitoring are also introduced
Keywords :
electric generators; electric motors; insulation testing; machine insulation; machine testing; monitoring; partial discharge measurement; dynamic stagnation voltage; generator/motor stator insulation; insulation breakdown testing; online partial discharge monitoring system; partial discharge activities; partial discharge magnitude; selected frequency bands; Costs; Digital filters; Frequency domain analysis; Insulation; Monitoring; Partial discharge measurement; Partial discharges; Space vector pulse width modulation; Stators; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Machines and Systems, 2001. ICEMS 2001. Proceedings of the Fifth International Conference on
Conference_Location :
Shenyang
Print_ISBN :
7-5062-5115-9
Type :
conf
DOI :
10.1109/ICEMS.2001.970679
Filename :
970679
Link To Document :