DocumentCode
1994573
Title
Experimental research of averaging Pitot tube with rotameter
Author
Sun, Chao ; Sun, Lijun ; Qiu, Xiang ; Zhang, Tao
Author_Institution
Tianjin Key Lab. of Porcess Meas. & Control, Tianjin Univ. Tianjin, Tianjin, China
fYear
2011
fDate
16-18 Sept. 2011
Firstpage
4502
Lastpage
4505
Abstract
The differential pressure exported by the averaging Pitot tube is small, it requires an expensive micro-scale differential pressure transducer with very good performance. In order to overcome this drawback, a rotameter was used to take place of the differential pressure transducer in the paper. The rotameter and the main pipe are in parallel lines, so that the rotameter is a by-pass pipe. The scale of the rotameter can reflect the flow rate of the main pipe indirectly. A mathematical model can be gotten according to the experiment, and then linear fitted the curve of the flow rate, so that an easier mathematical model can be obtained. In three different conditions, the method of the averaging Pitot tube with rotameter and the linear fitted model were verified. It is shown in the experiment that, the relative error between the calculated flow rate and the actual flow rate can reach 2.79%. If the requirement of the accuracy is low, this method can satisfy the requirements in the industrial fields.
Keywords
flowmeters; pipe flow; averaging Pitot tube; by-pass pipe; differential pressure; flow rate; main pipe; rotameter; Accuracy; Electron tubes; Equations; Fitting; Fluid flow measurement; Mathematical model; Roads; averaging Pitot tube flowmeter; bypass rotameter; flow measurement; linear fitting; mathematical model;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical and Control Engineering (ICECE), 2011 International Conference on
Conference_Location
Yichang
Print_ISBN
978-1-4244-8162-0
Type
conf
DOI
10.1109/ICECENG.2011.6058053
Filename
6058053