Title
The simulation of stray losses in a power transformer based on FEM
Author
Song, Zhanhai ; Gong, Kun ; Mou, Shuai ; Zhu, Yinhui ; Xiang, Bingfu ; Zhou, Ce
Author_Institution
Sch. of Phys. & Electron. Inf. Eng., Wenzhou Univ., Wenzhou, China
fYear
2011
fDate
16-18 Sept. 2011
Firstpage
4199
Lastpage
4201
Abstract
The leakage magnetic fields and the stray losses in a power transformer are analyzed base on three dimension finite element method, this electromagnetic model established can give the correct winding losses; the stray losses in tank wall are studied when magnetic shunts are used or not used beside the tank wall, the simulated stray losses are in accordance with the measured, which implies the model used in the paper is correct. By the proper use of magnetic shunts, stray losses in tank wall can be reduced effectively.
Keywords
finite element analysis; power transformers; FEM; electromagnetic model; leakage magnetic fields; magnetic shunts; power transformer; stray loss; tank wall; three dimension finite element method; winding loss; Analytical models; Eddy currents; Finite element methods; Loss measurement; Magnetic losses; Power transformers; Solid modeling; Transformer; finite element method; magnetic shunt; tank loss;