Further progress on lateral flow estimation using speckle size variation with scan direction
Author
Xu, Tiantian ; Bashford, Gregory R.
Author_Institution
Dept. of Biol. Syst. Eng., Univ. of Nebraska-Lincoln, Lincoln, NE, USA
fYear
2009
fDate
20-23 Sept. 2009
Firstpage
1383
Lastpage
1386
Abstract
Conventional blood flow velocity measurement using ultrasound is capable of resolving the axial component (i.e., that aligned with the ultrasound propagation direction) of the blood flow velocity vector. However, these Doppler-based methods are incapable of detecting blood flow in the direction normal to the ultrasound beam. In addition, these methods require repeated pulse-echo interrogation at the same spatial location. In this paper, we report additional data on a new method recently introduced. This method estimates the lateral component of blood flow within a single image frame using the observation that the speckle pattern corresponding to the blood reflectors (typically red blood cells) stretches (i.e., is ?smeared?) if the blood is moving in the same direction as the electronically-controlled transducer line selection in a 2D image. The situation is analogous to the observed elongation of a subject photographed with a moving camera. Experiments were performed with a blood flow phantom and high-frequency transducer of a commercially available ultrasound machine. Data was captured through an interface allowing access to the raw beamformed data. Blood flow with velocities ranging from 50 to 110 cm/s were investigated in this paper. Previously, we showed results indicating a linear relationship between the reciprocal of the speckle stretch factor and blood flow velocity when the scan velocity is greater than the blood flow velocity [1]. When the scan velocity is 64.8 cm/s, compared with the theoretical model, fitting results based on experimental data gave us a linear relationship with average flow estimation error of 1.74?1.48 cm/s. When the scan velocity is 37.4 cm/s, the average estimation error is 0.65?0.45 cm/s. The new experiments reported here include blood flow velocities that are close to and greater than the scan velocity. Results show that the linear relationship degrades under these conditions, which we hypothesize is due to speckle decorrelation and- flow gradients.
Keywords
biomedical transducers; biomedical ultrasonics; cellular biophysics; haemodynamics; haemorheology; phantoms; 2D image; beamformed data; blood flow; blood flow phantom; blood reflectors; electronically-controlled transducer line selection; elongation; flow gradients; high-frequency transducer; lateral flow estimation; scan direction; scan velocity; single image frame; speckle decorrelation; speckle pattern; speckle size variation; speckle stretch factor; ultrasound machine; ultrasound red blood cells; Blood flow; Cameras; Estimation error; Imaging phantoms; Red blood cells; Spatial resolution; Speckle; Ultrasonic imaging; Ultrasonic transducers; Velocity measurement; blood flow; speckle size; velocity measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Ultrasonics Symposium (IUS), 2009 IEEE International
Conference_Location
Rome
ISSN
1948-5719
Print_ISBN
978-1-4244-4389-5
Electronic_ISBN
1948-5719
Type
conf
DOI
10.1109/ULTSYM.2009.5441582
Filename
5441582
Link To Document