• DocumentCode
    1995756
  • Title

    Challenges with acoustic backing of CMUT arrays on silicon with integrated electronics

  • Author

    Berg, Sigrid ; Rønnekleiv, Arne

  • Author_Institution
    Dept. of Electron. & Telecommun., Norwegian Univ. of Sci. & Technol., NTNU, Trondheim, Norway
  • fYear
    2009
  • fDate
    20-23 Sept. 2009
  • Firstpage
    980
  • Lastpage
    983
  • Abstract
    Capacitive micromachined ultrasonic transducers (CMUTs) have in the last decade shown promising qualities for medical imaging. But there are some acoustical challenges that have to be overcome before the performance of a CMUT array with integrated electronics is satisfactory. Acoustic backing is necessary to avoid surface acoustic waves (SAW) excited in the surface of the silicon substrate to affect the transmit pattern from the array. For the backing to be able to damp the SAW, the silicon wafer stack has to be thin enough for some of the acoustic energy to reach the backing. We will present simulations showing that the thickness of the silicon substrate and thicknesses and acoustic properties of the bonding material have to be considered, especially when designing high frequency transducers. Through simulations we compare the acoustic properties of 3D stacks bonded with three different bonding techniques; anisotropic conductive adhesives (ACA), Solid-Liquid Interdiffusion (SLID) bonding and direct fusion bonding. We look at a CMUT array with a center frequency of 30 MHz and three silicon wafers underneath. We find that fusion bonding is most beneficial if we want to prevent surface waves from damaging the array response, but SLID and ACA are also promising if bonding layer thicknesses can be reduced.
  • Keywords
    acoustic intensity; biomedical ultrasonics; capacitive sensors; diffusion bonding; micromechanical devices; substrates; ultrasonic transducer arrays; CMUT array; acoustic backing; acoustic energy; anisotropic conductive adhesives; array response; array transmit pattern; bonding material; bonding technique; capacitive micromachined ultrasonic transducer; direct fusion bonding; high frequency transducers; integrated electronics; medical imaging; silicon substrate thickness; silicon wafer stack; solid-liquid interdiffusion bonding; surface acoustic waves excition; Acoustic arrays; Acoustic waves; Biomedical acoustics; Biomedical imaging; Conducting materials; Frequency; Silicon; Surface acoustic waves; Ultrasonic transducers; Wafer bonding;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium (IUS), 2009 IEEE International
  • Conference_Location
    Rome
  • ISSN
    1948-5719
  • Print_ISBN
    978-1-4244-4389-5
  • Electronic_ISBN
    1948-5719
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2009.5441611
  • Filename
    5441611