Title :
Protocols and standard crate configuration for a typical CDF Run 2 readout crate
Author :
Shaw, Esa M. ; Stuermer, Walter ; Wesson, Thomas R. ; Wilson, Peter J.
Author_Institution :
Fermilab, Batavia, IL, USA
Abstract :
This paper describes a standard for the readout and the trigger interface of a VMEbus based crate to be used by the front-end and trigger electronics of the CDF Run 2 experiment. Hereafter, this crate is referred to as the CDF Readout Crate. The goal is to standardize the implementation of functions that are common among all systems (i.e. power distribution, timing signals, DAQ functions) while allowing some flexibility with other functions (e.g. cooling, rear transition modules, J3 backplanes, etc.). This allows designers of cards that satisfy this standard to have access to a common well defined crate system with interfaces to the trigger and DAQ system, allowing them to concentrate their efforts on the functions they need. This paper lists the mechanical specifications, readout scheme, backplane and signal distribution specifications of the CDF Readout Crate. The paper also goes into some detail on the TRigger And Clock+Event Readout (TRACER) module, a common CDF crate module which provides the crate interface to the system clock and the trigger system
Keywords :
data acquisition; nuclear electronics; readout electronics; transport protocols; CDF Readout Crate; DAQ functions; J3 backplanes; cooling; front-end electronics; mechanical specifications; power distribution; protocols; readout scheme; rear transition modules; signal distribution specifications; standard crate configuration; timing signals; trigger electronics; trigger interface; typical CDF Run 2 readout crate; Backplanes; Bandwidth; Clocks; Data acquisition; Electronics cooling; Pins; Power distribution; Protocols; Rabbits; Timing;
Conference_Titel :
Nuclear Science Symposium, 1999. Conference Record. 1999 IEEE
Conference_Location :
Seattle, WA
Print_ISBN :
0-7803-5696-9
DOI :
10.1109/NSSMIC.1999.842492