• DocumentCode
    1997424
  • Title

    Measurements of body impedance for ESD

  • Author

    Wu, Zhancheng ; Huang, Jiusheng ; Liu, Shanghe

  • Author_Institution
    Institute of Applied Electrostatics 97 He Ping West Street ShiJiaZhang, 050003, P. R. China
  • fYear
    1997
  • fDate
    25-25 Sept. 1997
  • Firstpage
    132
  • Lastpage
    134
  • Abstract
    High voltage, short duration electrostatic discharge (ESD) measurements of human body impedance have been accomplished for different paths through the body. Skin contact impedance and intemal body impedance between various locations on the body were examined. Voltages from 1000 to 5000V were applied and the peak currents is 2.0 to 10A. The current waveform has time constant from 0.25 to 1.25 μs. The short time constant is consistent with safety requirements. The body impedance between the palm of the hand and the sole of the feet was found to be about 520 to 550Ω.
  • Keywords
    Capacitors; Current measurement; Electrostatic discharge; Electrostatic measurements; Humans; Impedance measurement; Low voltage; RLC circuits; Skin; Steady-state;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Overstress/Electrostatic Discharge Symposium,1997. Proceedings
  • Conference_Location
    Orlando, FL, USA
  • Print_ISBN
    1-878303-69-4
  • Type

    conf

  • DOI
    10.1109/EOSESD.1997.634235
  • Filename
    634235